Page 1 - Product Manual

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Medalist 8421, Medalist 6421. . . . . . . . . . . . . . . . . . . . . . . . .

Page 2

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 3 Track-to-track seek time (msec typical) 2.0 (read), 2.75 (write)Average seek time (msec ty

Page 3

4 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. AVibration, operating 0.5 Gs (0 to peak, 5–350 Hz)Vibration, nonoperating 5 Gs (0 to peak, 5–350 Hz)

Page 4 - Contents

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 5 1.0 Drive specificationsUnless otherwise noted, all specifications are measured under amb

Page 5

6 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. A1.3 Recording and interface technology1.4 Physical characteristics1.5 Seek timeSeek measurements

Page 6

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 7 •Average seek time is a true statistical random average of at least 5,000measurements of s

Page 7

8 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. A•Seek ModeDuring seek mode, the read/write actuator arm moves toward aspecific position on the disc

Page 8

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 9 1.7.1.1 Typical current profileFigure 1 shows a typical current profile. Figure 1. Typ

Page 9 - Specification summary table

10 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. A1.7.2 Conducted noiseInput noise ripple is measured at the host system power supply acrossan equi

Page 10

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 11 drive buffer is enabled, the heads are parked and the spindle is at rest.The drive accept

Page 11

12 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. A1.8.3.2 Wet bulb temperature1.8.4 Altitude1.8.5 ShockAll shock specifications assume that the

Page 12 - 1.0 Drive specifications

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Medalist 8421, Medalist 6421. . . . . . . . . . . . . . . . . . . . . . . . .

Page 13 - 1.5 Seek time

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 13 1.8.6.1 Operating vibrationThe following table lists the maximum vibration levels that

Page 14

14 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. A1.10 Electromagnetic susceptibilityThe drive operates without errors when subjected to the follow

Page 15

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 15 comply with the directives when used in the test systems, we cannotguarantee that all sys

Page 16

16 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. AIf necessary, you should consult your dealer or an experienced radio/television technician for add

Page 17

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 17 2.0 Configuring and mounting the driveThis section contains the specifications and instr

Page 18

18 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. A2.2 Jumper settings2.2.1 Master/slave configurationThe options jumper block (J8) shown in Figure

Page 19

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 19 2.2.2 Cable-select optionComputers that use cable-select determine the master and slave

Page 20 - 1.9 Drive acoustics

20 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. AFigure 3. Mounting dimensions—top, side and end view1.00 ± 0.028(25.4 ± 0.7)3.72 ± 0.03(94.5 ± 0.

Page 21 - 1.12.1 Safety certification

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 21 3.0 ATA interface These drives use the industry-standard ATA task file interface thatsup

Page 22 - 1.12.3 FCC verification

22 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. AFigure 4. I/O pins and supported ATA signalsReset–GroundDD7DD8DD6DD9DD5DD10DD4DD11DD3DD12DD2DD13DD

Page 23

1999 Seagate Technology, Inc. All rights reservedPublication Number: SG35116-001, Rev. A, February 1999Seagate, Seagate Technology and the Seagate lo

Page 24

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 23 3.2 ATA Interface commands3.2.1 Supported ATA commandsThe following table lists ATA-sta

Page 25 - 2.2 Jumper settings

24 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. A3.2.2 Identify Drive commandThe Identify Drive command (command code ECH) transfers informationab

Page 26

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 25 Word Description Value0Configuration information:• Bit 15: 0 = ATA; 1 = ATAPI• Bit 7: rem

Page 27

26 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. A27–46 Drive model number: (40 ASCII char-acters, padded with blanks to end of string)ST32112AST343

Page 28 - 3.0 ATA interface

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 27 63 Multiword DMA active and modes supported (see note following this table)xx07H64 Advanc

Page 29

28 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. A91–92 ATA-reserved0000H93 Hardware Reset Value (see description following this table)4000H94–127 A

Page 30 - 3.2.1 Supported ATA commands

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 29 3.2.3 Set Features commandThis command controls the implementation of various features t

Page 31 - 3.2.2 Identify Drive command

30 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. ANote. At power-on, or after a hardware or software reset, the defaultvalues of the features are as

Page 32

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 31

Page 33

32 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. A

Page 34

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A iiiContentsSpecification summary table . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 35

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 33 Seagate Technology, Inc.920 Disc Drive, Scotts Valley, California 95066, USAPublication N

Page 36 - 3.2.3 Set Features command

iv Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A2.0 Configuring and mounting the drive . . . . . . . . . . . . . . . . . . . 172.1 Han

Page 37 - 3.2.4 S.M.A.R.T. commands

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A vFiguresFigure 1. Typical startup and operation current profile . . . . . . . . . . . . 9Fi

Page 38

vi Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A

Page 39

Medalist 8421, 6421, 4311 and 2112 Product Manual, Rev. A 1 IntroductionThis manual describes the functional, mechanical and interface specifi-cations

Page 40 - Seagate Technology, Inc

2 Medalist 8421, 6421, 4311 and 2112 Manual, Rev. ASpecification summary tableThe specifications listed in this table are for quick reference. For det