Pulsar XT.2 SAS Product Manual, Rev. B 25
[1] Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these values. Power
supply at nominal voltage. N (number of drives tested) = 6, 60 Degrees C ambient.
[2] For +12 V, a –10% tolerance is allowed during initial start but must return to ±5% before reaching ready state. The
±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is
able to accept selection by the host initiator.
[3] See +12V current profile in Figure 4 (for 400GB models) and Figure 5 (for 200GB models).
[4] See +12V current profile in Figure 6 (for 100GB models).
[5] This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup
primitive.
[6] See paragraph 7.3.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient
response.
Table 10: 100GB standard model DC power requirements
Parameter 100GB (6.0Gb)
Regulation ±5% ±5%
Voltage +5V +12V
Current (A) Current (A) Power (W)
Average idle current
DC
0.40 0.17 4.04
Maximum starting current
(peak DC) DC 3σ 1.09 0.31
(peak AC) AC 3σ 1.16 0.73
Delayed start (max) DC 3σ 0.43 0.18 4.31
Peak operating current (random read):
Typical DC DC 0.46 0.21 4.82
Maximum DC 3σ 0.49 0.23 5.21
Maximum (peak) DC 3σ 0.80 0.72
Peak operating current (random write)
Typical DC DC 0.45 0.25 5.25
Maximum DC 3σ 0.49 0.26 5.57
Maximum (peak) DC 3σ 0.71 0.54
Peak operating current (sequential read)
Typical DC DC 0.54 0.28 6.06
Maximum DC 3σ 0.58 0.29 6.38
Maximum (peak) DC 3σ 0.80 0.58
Peak operating current (sequential write)
Typical DC DC 0.53 0.36 6.97
Maximum DC 3σ 0.57 0.37 7.29
Maximum (peak) DC 3σ 0.82 0.82