15.29
InForm OS Version 2.2.4 Command Line Interface Reference
–filt <fspec>
Specifies that histograms below the threshold specified by the <fspec> argument are not
displayed. The
<fspec> argument is specified in the syntax of <op>,<val_ms>,<count>.
<op>
The <op> argument can be specified as one of the following:
r - Specifies read statistics.
w - Specifies write statistics.
t - Specifies total statistics.
rw - Specifies total read and write statistics.
<val_ms>
Specifies the threshold service time in milliseconds.
<count>
Specifies the minimum number of access above the threshold service time.
–ni
Specifies that histograms for only nonidle devices are displayed. This option is shorthand
for the option
–filt t,0,0.
SPECIFIERS
None.
RESTRICTIONS
None.