Seagate ST39103LC User's Guide Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
12 SVA Path User’s Guide
Command options that take arguments (shown in braces after the
command) require an argument and should not be run without one.
Table 3-1 setsp Command Options
Option Effect
-a
show current device configuration and state
-b{0|1}
set load balancing for a logical drive. (pages
24 and 27).
-b0 disables load balancing for the device;
-b1 enables it
Must be used with
-l
-d<n>
set a retry delay of n for a logical drive,
where n is the interval between retries in
milliseconds (page 24 and 27)
-e{0|1}
set exclusion for a logical drive (pages 24
and 26).
-e0 includes the device;
-e1 excludes it;
excluded devices are not accessible by user
applications;
devices are excluded by default
Must be used with
-l
-f{0|1}
set failback for a logical drive.
-f0 disables failback for the device;
-f1 enables it (pages 25 and 28)
Must be used with
-l
-g
generate configuration files after an sppath
command (Page 21)
-i
show contents of driver configuration files
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 67 68

Comments to this Manuals

No comments