Seagate ST34572WC Specifications Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
Act PV 1
Max PE per PV 4350
VGDA 2
PE Size (Mbytes) 4
Total PE 4340
Alloc PE 3740
Free PE 600
Total PVG 0
Total Spare PVs 0
Total Spare PVs in use 0
In this example, the total free space is 600 * 4 MB, or 2400 MB.
b. The logical volume is mirrored with a strict allocation policy, and there are not enough extents on
a separate disk to comply with the allocation policy. To confirm this, run lvdisplay to
determine which disks the logical volume occupies, and then check whether there is sufficient
space on the other disks in the volume group.
c. In a SAN environment, one of the disks was dynamically increased in size. LVM did not detect
the asynchronous change in size.
Recommended Action:
a. Choose a smaller size for the logical volume, or add more disk space to the volume group.
b. Choose a smaller size for the logical volume, or add more disk space to the volume group.
Alternatively, free up space on an available disk using pvmove.
c. None. LVM does not support dynamic resizing of disks.
"m": Illegal option.
Cause:
The system does not have HP MirrorDisk/UX installed.
Recommended Action:
Install HP MirrorDisk/UX.
lvlnboot
lvlnboot: Unable to configure swap logical volume. Swap logical volume size
beyond the IODC max address.
Cause:
The boot disk firmware cannot access the entire range of the swap logical volume. This happens with
older host bus adapters when primary swap is configured past 4 GB on the disk.
Recommended Action:
Upgrade the system firmware or use a newer host bus adapter that supports block addressing. If
neither of these actions are successful, reduce the size of the primary swap logical volume so that it
does not exceed 4 GB.
pvchange
"a": Illegal option.
Cause:
LVM OLR is not installed.
Recommended Action:
Install the patches enabling LVM OLR, or use an alternate replacement procedure.
The HP-UX kernel running on this system does not provide this feature. Install
the appropriate kernel patch to enable it.
30