Chapter 6 Troubleshooting Common Problems 6-13
Both of these bugs might be due to a known problem with Vixel 1000 hubs, Sun’s
only hub product as of October 2000. The hub doesn’t propagate the link failure
back to the host, so if the path is lost on the array side of the hub, there is no
notification sent to the host. Resetting the loop via software will rectify the
problem.
6.6 GUI Hang
Sometimes certain RAID Manager 6 applications such as Recovery or Maintenance
will stop responding, either showing an hour glass or appearing to be dead.
Arraymon polls the devices every few seconds as well as when each application is
started. An unresponsive device can cause this. Killing the application by PID and
restarting RAID Manager 6 is a reasonable workaround. For A3500FC connected
arrays, using luxadm or sansurfer to reset the FC loop is also effective.
Also be aware that certain processes such as LUN reconstruction can take as long as
five minutes to complete.
6.7 Drive Spin Up Failure, Drive Related
Problems
Sometimes drives in an A3x00 disk array will fail without any apparent reason when
the host is rebooted. Refer to bug 4253002.
This bug is fixed in the RAID Manager 6.1.1 Update 2 with patch no. 106513-5 or
RAID Manager 6.22x.
There is another problem with drives failing to spin up due to the Calico chip in
some Seagate drives. See patch no. 106817-3.