Chapter 4 System Software Installation and Configuration 4-11
/net/artemas.ebay/global/archive/StorEdge_Products/
sonoma/rm_6.1.1_u2/FCS/Tools
or
/net/artemas.ebay/global/archive/StorEdge_Products/
sonoma/rm_6.22/Tools
Note Adding support of more LUNs than you need extends the time required for
reboot and the response time of the RAID Manager 6 GUI because it has to scan all
the potential LUNs. See FIN I0551-1 or later.
Common problem—RAID Manager 6 is unable to communicate with the module
but lad shows more then 8 LUNs.
Solution—Re-run addXXlun.sh followed by boot -r or hot_add.
4.6 SNMP
See the "Setting Up SNMP Notification" section in Chapter 4 in the Sun StorEdge
RAID Manager 6.22 Installation and Support Guide for details.
Note In order for SNMP to be properly configured, DNS must be enabled unless
you apply the workaround described in bug 4348634.
The SNMP trap data that is supported by the A3x00/A3500FC controllers is covered
in the MIB definition included with the RAID Manager host software.
See the following file:
/net/artemas.ebay/global/archive/StorEdge_Products/
sonoma/rm_6.22/rm6_22_FCS/Product/SUNWosau/reloc/lib/osa/
rm6traps.mib
Also refer to the RAID Manager software documentation online: