4-4 Sun StorEdge A1000 and A3x00/A3500FC Best Practices Guide November 2002
sd_error_level = 2 or 0 (for A3x00 SCSI)
ssd_error_level = 2 or 0 (for A3500FC)
RdacDebug = 1 (for both SCSI and FC)
You can set the variables in two ways:
adb -kw
You can add the variables to the end of /etc/system, followed by a reboot. See
the man page system (4) for further details.
With the variables set, all failed command descriptor block (CDB) and retry
commands will appear on the console and in /var/adm/messages. Be sure enough
space is available on /var/adm, if file system size is limited.
4.3 format and lad
Keeping the lad/RM6 ctd assignment in sync with format is neither necessary nor
practical.
lad/RM6 reports the current device path to LUNs. The path changes when LUNs are
moved between controllers.
format reports the device path based on entries in/dev/[r]dsk. These entries are
created at the end of the LUN creation process. These are static, thus presenting a
fixed reference to the application no matter which controller owns the LUN.
If you want to keep the ctd# in sync, refer to the following white paper available on
the Sonoma Engineering web site for a RAID Manager 6.1 solution:
http://webhome.sfbay/A3x00/Sonoma/4084293
For a RAID Manager 6.22x solution for keeping the ctd# in sync, see the man page
rdac_address (4).
Note format should report the LUNs as a pseudo device (for example
/pseudo/rdnexus...). If the path indicates physical devices (for example
/sbus@...), then this indicates that the LUNs were not built properly.