Chapter 6 Troubleshooting Common Problems 6-7
Adding drives from another A3x00 while the system is powered down can cause
loss of LUN configuration as described in bug 4133673.
6.3 Rebuilding a Missing LUN Without
Reinitialization
This section covers the following topics:
Section 6.3.1, “Setting the VKI_EDIT_OPTIONS” on page 6-7
Section 6.3.2, “Resetting the VKI_EDIT_OPTIONS” on page 6-9
Section 6.3.3, “Deleting a LUN With the RAID Manager GUI” on page 6-9
Section 6.3.4, “Recreating a LUN With the RAID Manager GUI” on page 6-9
Section 6.3.5, “Disabling the Debug Options” on page 6-10
Rebuilding a missing LUN without reinitalizing it can be dangerous, because data
might get lost permanently. Use the following procedure only as a last resort after all
attempts of recovery have failed.
The process of recreating a missing LUN or deleting a LUN if needed requires you to
use the controller serial port and the RAID Manager GUI. You might need to recreate
a LUN when it is missing after a reboot of a controller.
Before you begin to recreate a LUN, make sure of the following:
A copy of the module profile prior to the disaster is available before attempting to
recreate a LUN.
Use the procedures for recreating a LUN if you know that the data is still intact.
Note If you are recreating LUN 0 and if LUN 0 is greater than 10MB (for example
36GB RAID 5), and the module profile shows that it is only equal to 10MB, stop. Do
not proceed with this procedure. You will not be able to recover LUN 0.
6.3.1 Setting the VKI_EDIT_OPTIONS
If the system has dual controllers, set the VKI_EDIT_OPTIONS on both controllers
as follows.
1. At the RAID controller shell prompt, enter:
->
VKI_EDIT_ OPTIONS
Page view 96