Chapter 5 Maintenance and Service 5-7
5.1.5 SCSI ID Jumper Settings
The controller module SCSI ID can be changed, if necessary, by the use of jumpers.
The SCSI ID jumper block is located at the rear of the SCSI controller module. See
Section 2.3 “Verifying Controller Module ID Settings” in the Sun StorEdge
A3500/A3500FC Hardware Configuration Guide for detailed instructions. The factory
default settings are shown in
TABLE 5-1.
5.1.6 SCSI Termination Power Jumpers
There are two SCSI termination power jumpers located at the rear of the SCSI
controller module. One is located below and to the left of the J11 connector (DIFF
SCSI ARRAY 1). The other is located below and to the right of the J4 connector (DIFF
SCSI HOST B). These jumpers enable the controller boards to supply SCSI
termination power to the host SCSI bus. Do not remove these jumpers.
5.1.7 LED Indicators
See Section 4.1 “Checking the Controller Module LEDs” in the Sun StorEdge
A3500/A3500FC Controller Module Guide for detailed information on checking the
controller module LEDs.
5.1.8 Backplane Assembly
Backplane failures are rare. There are no active devices on the backplane.
5.1.9 D1000 FRUs
Refer to the following web site for a listing of the D1000 FRUs:
http://infoserver.central/data/syshbk
TABLE 5-1 Controller Module SCSI ID Settings
Controller SCSI ID
A5
B4
Page view 76